We Are Specialization in Central Medical Gas Pipeline System

COMPANY PROFILE 
ABOUT US

M/s SPS Meditech Systems is a registered firm working in various fields i.e. Medical Gas Pipeline, Pre-Fabricated Modular Operaon ̀ Theaters, IVF Lab, Electrical, Plumbing, Fire Fighng ̀ & HVAC Systems, Hospital All Interior which deals in Total Hospital Projectsand Products.

M/s SPS Meditech Systems is a Group of the most Intelligent Personalies ̀ which are working for the last 12 years in Health Care Projects.
Our HealthCare Projects and producon ̀ team is headed by Industries leading teams. Today the company pracces ̀ stringent quality standards and have uncompromising About Us Today the company pracces ̀ stringent quality standards and have uncompromising commitment towards complete Customer sasfacon. ̀

M/s SPS Meditech Systems has its Independent design & engineering wing with qualified engineers and headed by good management personnel having thorough knowledge of naonal ̀ and internaonal ̀design codes such as HTM0201, SB, NABH, NBC, TAC, NFPA. NEC etc. M/s SPS
Meditech Systems have efficient project management department monitored by well qualified management for complete customer sa. sfacon and to ensure melycompleon of the job.

Company has adequate qualified project man power that is fully empowered to take the decision and get the job done. The company job is not finished once the system is installed & commissioned. It has a comprehensive servicing, tesng & upgrading capability which ensure to our presgious customers that the installaon will connue effecvely for the years to come

GAS PIPELINE

WhatsApp Image 2023-12-24 at 1.47.28 PM
WhatsApp Image 2023-12-24 at 1.47.33 PM
WhatsApp Image 2023-12-24 at 1.47.27 PM
WhatsApp Image 2023-12-24 at 1.47.26 PM (1)
WhatsApp Image 2023-12-24 at 1.47.27 PM
WhatsApp Image 2023-12-24 at 1.47.26 PM
WhatsApp Image 2023-12-24 at 1.47.24 PM
WhatsApp Image 2023-12-24 at 1.47.22 PM
WhatsApp Image 2023-12-24 at 1.47.25 PM (2)
previous arrow
next arrow

Our Services

We Are Specialization in Central Medical Gas Pipeline System

INSTALLATION & TESTING

Installaon of piping shall be carried out with utmost
cleanliness. Only pipes, fings and valves which have pipes,
fings and valves which have been de-greased and fings
brought in polythene sealed bags shall be used at site. Pipe
fixing clamps shall be of nonferrous or non deteriorang plasc
suitable for the diameter of the pipe. All joints shall be made of
copper to copper and brazed by silver brazing filler material.

Medical Air Compressor

  • MEDICAL COMPRESSED AIR COMBINED AIR PLANT
  • AND SURGICAL AIR PLANT (4BAR,7BAR)
  • Air Plant System The Medical Air system shall conform to NFPA 99/ENsystem shall conform to NFPA 99/EN

  • ISO7396-1/HTM02-01.Medical quality air to the European Pharmacopoeia monograph shall be delivered at pressures of 700kPa (7 bar) gauge for supply of the hospital medical or surgical air The entire system shall be ‘ Triplex” such that any single functional component failure will not affect the integrity of the medical compressed air supply.

Vacuum Plant

Vacuum system fully compliant to NFPA 99/EN ISO 7396-
1/HTM02-01 standards The Medical Vacuum System shall
ensure the minimum pipeline. Vacuum level of 450mmHg is
maintained at the plant service connecon point at the plant
service connecon point at the rated volumetric ‘free air’ flow
rate with two pumps in standby. The bacteria filtraon system
shall be ‘duplexed’ such that each filter can be isolated for
replacement of the filter.

We Are Specialization In

Modular Operation theater System

  • Walls and Ceiling Systems (PUFF
  • Automated Operated Hermetically sealed Sliding
  • Plainer Ceiling
  • Surgeon Control
  • Single arm and Doable arm surgeon
  • Single arm and Doable arm surgeon
  • Single arm and Doable arm Anesthesia
  • Pressure Relief Dampers (PRD).
  • X-Ray Viewing
  • Operating writing List
  • Peripheral Lights (LED light).
  • Conductive Storage Units.
  • Pass Air Handling Unit(AHU).

We are here

  • It meets the four major criteraas required for T’S
  • To control the Temperature & Humidity of space
  • To assist in the removal and dilution of waste anesthetic
  • To dilute Airborne Bacterial
  • To control the movement of air within the
  • To create bacteria free environment

Why Do We Require Pre-Fabricated MOT

The Principal living reservoir of human disease is the human body itself.

  • It is estimated that between 5% to 15% of all hospital patients acquire some form of nosocomial infection (Hospital stay acquired infection)
  • Surgical wound infections account for over 25% of recorded cases of nosocomial
  • Nosocomial infections result from the interaction of several factors
  • Micro-Organisms in the Hospital
  • The Compromised (weakended) status of the
  • Chain of transmission

 

Standard Equipment / Accessories ICU

  1. The patient compartment and driver’s cabin should be
  2. Stretcher
  3. Medicine
  4. Oxygen cylinder cage with cylinder (ISI), flow meter (ISI), humidifier (ISI) and one set of mask and tubing for adult and pediatric , located suitably to give oxygen to the patients. Explosive certificate for Oxygen cylinder to be The cylinder has to be provided in completely filled condition.
  5. IV hook on the top roof on at least 3
  6. The Light bar should be Rhombus shaped, Double layered structure, Combination of continually lit, turning lamps and flash lights, High quality tungsten bulbs and xenon lamp tubes, Long life span, high quality tungsten bulbs and xenon lamp tubes, Long life span, high luminance, Voltage: DC 12V, with integrated Public addressing systems of Should have unique high intensity Siren with revolving flashers and lights indicating emergency while transferring a serious patient. Siren should have five different tones that can be interchanged in order to draw attention of public and take way in high density traffic. The control panel for this system should be fixed at a suitable location in the driver compartment.
  7. Doctors
  8. Squad bench for patient attainders for at least 3
  9. Electric fan -2 noson both (If air-conditioner is provided as standard in the offered ambulance then fans are not required.
  10. Exterior design / painting . All vinyl / reflective stickers/ retro reflective stickers/films to be used. After finishing the sticker works as per the design provided by the Tender Inviting Authority has to be laminated or coated with suitable transparent paint. Detailed drawing and details will be furnished at the time of issue of LOI or Supply order.

Message Us